The Role of Stereopsis in Microsurgical Performance on the EYESi Ophthalmic Surgical Simulator
dc.contributor.author | Alkharashi, Hanouf | |
dc.contributor.copyright-release | Not Applicable | en_US |
dc.contributor.degree | Master of Science | en_US |
dc.contributor.department | Department of Clinical Vision Science | en_US |
dc.contributor.ethics-approval | Received | en_US |
dc.contributor.external-examiner | David Clarke | en_US |
dc.contributor.graduate-coordinator | Darren Oystreck | en_US |
dc.contributor.manuscripts | Not Applicable | en_US |
dc.contributor.thesis-reader | Leah Walsh | en_US |
dc.contributor.thesis-reader | David Westwood | en_US |
dc.contributor.thesis-supervisor | Robert LaRoche | en_US |
dc.date.accessioned | 2019-04-05T17:36:14Z | |
dc.date.available | 2019-04-05T17:36:14Z | |
dc.date.defence | 2019-03-28 | |
dc.date.issued | 2019-04-05T17:36:14Z | |
dc.description.abstract | There remains a lack of objective evidence on whether stereopsis is necessary for an ophthalmic surgical career. The present study attempts to address this question by evaluating the surgical performance of subjects with different levels of stereoacuity using a virtual reality intraocular surgical simulator (EYESi, VRmagic Holding AG, Mannheim, Germany). Subjects were tested based on their stereoacuity level and stratified in 3 age-matched groups: normal stereo, subnormal stereo and patients with no measurable steroacuity. Subjects performed 3 attempts on a standardized microsurgical module on the EYESi VR simulator. Mixed repeated measure ANOVA was used for statistical analysis. This study showed that the simulated microsurgical performance on the EYESI intraocular surgical simulator of individuals with reduced and absent stereoacuity were statistically indistinguishable from those with normal stereoacuity. | en_US |
dc.identifier.uri | http://hdl.handle.net/10222/75446 | |
dc.language.iso | en_US | en_US |
dc.subject | Stereopsis | en_US |
dc.subject | Virtual Reality | en_US |
dc.subject | Surgical simulation | en_US |
dc.subject | EYESi | en_US |
dc.subject | Stereoblindness | en_US |
dc.subject | Surgical Simulator | en_US |
dc.title | The Role of Stereopsis in Microsurgical Performance on the EYESi Ophthalmic Surgical Simulator | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Alkharashi-Hanouf-MSc-CVS-April-2019.pdf
- Size:
- 4.33 MB
- Format:
- Adobe Portable Document Format
- Description:
- MSc. Thesis
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: