dc.description.abstract | After brief comparison of ventilation schemes used in three long European tunnels, several possible
methods of ventilating a 13 km submarine vehicular tunnel are examined. Probably the most suitable
is one supplying fresh air from a smaller ventilation tunnel parallel to that carrying the traffic. | |
dc.description.abstract | Suivant une comparaison abrégée des schémas d'aération usagés dans trois longs tunnels européens, on a examiné les méthodes disponibles pour aérer un tunnel véhiculaire sous-marin, long de 13 km. II est probable que Ia méthode Ia plus propice serait une qui fournirait de I'air frais provenant d'un petit tunnel parallèle à celui où la cirulation prend place. | |