Show simple item record

dc.contributor.authorSadeghian, Pedram
dc.contributor.authorFam, Amir
dc.date.accessioned2017-07-20T14:43:04Z
dc.date.available2017-07-20T14:43:04Z
dc.date.issued2010-03-15
dc.identifier.citationSadeghian, Pedram, and Fam, Amir. (2010). Bond-Slip Analytical Formulation toward Optimal Embedment of Concrete-Filled Circular FRP Tubes into Concrete Footings. Journal of Engineering Mechanics, 136 (4), 524-533.en_US
dc.identifier.urihttp://hdl.handle.net/10222/73045
dc.description.abstractThis paper presents a robust analytical model for a moment connection of concrete-filled fiber reinforced-polymer (FRP) tubes (CFFTs) to concrete footings. The CFFT connection is based on a simple approach of direct embedment into the footing, thereby eliminating the need for connection rebar or mechanical devices. The CFFT is externally subjected to lateral and axial loads, resembling practical applications such as piles affixed to pile caps, bridge columns, or utility poles. The model adopts the concepts of equilibrium, deformations compatibility, and nonlinear concrete stress-strain behavior. It also employs a “bond stress-slip” relation that can be obtained from simple push-through tests on some of the commercially used tubes. The model can predict the critical embedment length Xcr, which is the minimum length required to achieve material failure of the CFFT outside the footing, and bond failure inside the footing, simultaneously. If the actual embedment length is less than Xcr, bond failure occurs prematurely at a lower strength that can also be predicted by the model. The model was verified using experimental data and showed that Xcr was only 0.7 of the diameter for that case. A sensitivity parametric analysis was carried out that led to some approximations. Based on which, a simple closed-form expression was established for Xcr in the case of lateral loading only.en_US
dc.language.isoenen_US
dc.publisherAmerican Society of Civil Engineersen_US
dc.relation.ispartofJournal of Engineering Mechanicsen_US
dc.subjectConcrete-Filled FRP Tubesen_US
dc.subjectCFFTen_US
dc.subjectConnectionen_US
dc.subjectEmbedmenten_US
dc.subjectCompositeen_US
dc.subjectColumnen_US
dc.subjectFRPen_US
dc.subjectModelen_US
dc.subjectBonden_US
dc.subjectSlipen_US
dc.titleBond-Slip Analytical Formulation toward Optimal Embedment of Concrete-Filled Circular FRP Tubes into Concrete Footingsen_US
dc.typeArticleen_US
dc.identifier.volume136
dc.identifier.issue4
dc.identifier.startpage524-533
 Find Full text

Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record