Show simple item record

dc.contributor.authorNejad, AZ
dc.contributor.authorSun, M
dc.contributor.authorTousignant, K
dc.date.accessioned2024-02-26T20:48:30Z
dc.date.available2024-02-26T20:48:30Z
dc.date.issued2021-02-01
dc.identifier.citationPublished Version: Nejad, A. Z., Sun, M. & Tousignant, K. (2021). Circular hollow section X-connections near an open chord end: Stress concentration factors. Journal of Constructional Steel Research 177: 106454-1 – 106454-14.en_US
dc.identifier.urihttp://hdl.handle.net/10222/83468
dc.description.abstractThis paper presents a numerical finite element (FE) investigation to determine stress concentration factors (SCFs) for circular hollow section (CHS)-to-CHS X-connections near an open chord end. Previous large-scale experiments are used to validate FE models, and a parametric study is performed. The parametric study consists of 240 models with variations in chord slenderness (2γ), branch-to-chord diameter ratio (β), branch-to-chord thickness ratio (τ), and chord end distance (e) on one side of the of the connection. For each of the 240 models, SCFs are determined at the crown and saddle hot-spot stress locations. Extrapolating existing formulae to predict “end-distance effects” on SCFs at these locations in CHS-to-CHS X-connections, from CIDECT Design Guide 8 (DG8), is shown to be inaccurate. Hence, SCF correction coefficients (ψ) and parametric formulae to estimate ψ (based on e/d0, 2γ and β) are derived.en_US
dc.publisherElsevieren_US
dc.relation.ispartofJournal of Constructional Steel Researchen_US
dc.titleCircular hollow section X-connections near an open chord end: stress concentration factors (Postprint)en_US
dc.typeArticleen_US